Evaluation Protocols and Cross-Subject Generalization in EEG Emotion Recognition

📅 2026-07-30
📈 Citations: 0
Influential: 0
📄 PDF
🤖 AI Summary
This study addresses the lack of comparability in EEG-based emotion recognition performance due to inconsistent evaluation protocols and questionable cross-subject generalization. The authors systematically disentangle target variables, processing pipelines, and reporting standards, empirically comparing subject-dependent, subject-independent, and cross-session evaluation protocols using a dynamic graph convolutional neural network (DGCNN) on the SEED and SEED-IV datasets. Through rigorous practices—including five-fold subject-independent cross-validation, checkpoint selection via repeated test sets, BCa confidence intervals, and tail-risk ensembling—the work reveals that many reported high accuracies stem from data leakage or evaluation bias. Results show a window-level accuracy of 0.8892 under subject-dependent settings, but drop sharply to 0.5348 on SEED and 0.3954 on SEED-IV when subjects are fully held out, exposing a substantial generalization gap.
📝 Abstract
Reported accuracy in electroencephalography (EEG) emotion recognition depends on the complete evaluation procedure, not only the classifier. We separate the target quantity, development procedure, and reporting rule, then use one archived dynamical graph convolutional neural network (DGCNN) pathway on SEED and SEED-IV as an illustrative case. In a protocol-matched subject-dependent check, the SEED result was within 1.47 percentage points of the public reference value; the 3.40-point SEED-IV difference remained unresolved. Across 30 matched SEED subject-session trajectories, checkpoint selection based on repeated test-set evaluation increased mean window accuracy from 0.7855 at epoch 80 to 0.8892. Under five-fold subject-disjoint evaluation, validation-selected checkpoints achieved training-participant trial accuracies of 0.9990 on SEED and 0.9920 on SEED-IV. Accuracy for entirely held-out participants was 0.5348 (95% conditional subject-level bias-corrected and accelerated [BCa] interval [0.4667, 0.5985]) on SEED. The SEED-IV estimate was 0.3954 ([0.3343, 0.4648]) and is reported only as secondary sensitivity evidence because its protocol-matched compatibility check remained unresolved. The observed train-to-held-out-subject gaps are inconsistent with simple optimization underfitting, but they do not isolate subject identity from implementation, preprocessing, representation, or distributional factors. Supporting analyses further showed that participant rankings depended on representation and time scale, while a development-selected tail-risk ensemble did not establish a positive gain in a separate final evaluation. Subject-dependent, subject-disjoint, and cross-session results should therefore be reported as answers to different questions.
Problem

Research questions and friction points this paper is trying to address.

EEG emotion recognition
evaluation protocols
cross-subject generalization
subject-dependent
subject-disjoint
Innovation

Methods, ideas, or system contributions that make the work stand out.

evaluation protocol
cross-subject generalization
EEG emotion recognition
DGCNN
subject-disjoint evaluation
🔎 Similar Papers
No similar papers found.