This work addresses the challenge of depth reconstruction in compact laparoscopic systems, where conventional structured light methods—requiring multi-frame acquisition and precise projector-camera synchronization—are impractical. The authors propose a synchronization-free, single-shot depth estimation framework that integrates passive binary LED structured light, a VQ-VAE with a discrete latent space prior, and a custom U-Net depth prediction head to enable real-time, video-rate depth inference from a single frame in a dual-channel laparoscope. Notably, this is the first study to incorporate VQ-VAE latent representations into endoscopic depth reconstruction, achieving high-fidelity depth recovery without explicit segmentation and enabling deployment on low-complexity hardware. Experiments demonstrate state-of-the-art performance with a mean absolute error of 3.70 mm, 96.2% accuracy under the δ<1.1 metric, and an inference speed of 26.0 Hz, significantly outperforming existing baselines.
📝 Abstract
Significance. Accurate intraoperative depth perception is important for autonomous and semi-autonomous robotic laparoscopic surgery. Conventional fringe projection profilometry can achieve millimeter-scale accuracy but often requires multi-shot acquisition, digital-micromirror-device projection, and projector-camera synchronization, complicating integration into compact laparoscopic systems. Aim. To develop a synchronization-free, single-shot depth-sensing platform using a passive LED-illuminated binary mask and a VQ-VAE prior with a custom U-Net depth head. Approach. A compact projection module was coupled to one channel of a dual-channel laparoscope, while the second channel imaged the fringe-illuminated target. A Zivid 3D camera acquired reference depth for 722 paired phantom images. Zivid depth maps were reprojected into the SSLE image frame for supervised training and evaluation. The VQ-VAE encoded each input into a discrete latent representation, and a latent-space U-Net predicted depth without a separate mask-prediction branch. Results. Using a fixed train/validation/test split, the proposed model achieved an MAE of 3.70 mm, AbsRel of 0.0326, delta=1.1 accuracy of 0.962, and delta=1.1^2 accuracy of 0.970. It achieved lower MAE than the dual U-Net MaskNet + DepthNet baseline and outperformed off-the-shelf monocular depth models in MAE, AbsRel, and threshold accuracy. The pipeline operated at 26.0 Hz over 301 consecutive frames on an NVIDIA A100 GPU. Conclusions. The LED-illuminated binary-pattern platform with latent-space depth reconstruction enables synchronization-free, video-rate endoscopic depth estimation. Results demonstrate Zivid-referenced phantom reconstruction without an explicit segmentation stage, while emphasizing the importance of dataset size and SSLE-Zivid calibration accuracy.
Problem

Research questions and friction points this paper is trying to address.

depth reconstruction
single-shot
laparoscopic surgery
real-time
structured light
Innovation

Methods, ideas, or system contributions that make the work stand out.

single-shot depth reconstruction
VQ-VAE latent space
synchronization-free structured light
laparoscopic depth estimation
binary mask projection
🔎 Similar Papers
No similar papers found.
W
Wayne Wonseok Rodgers
Johns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States; Johns Hopkins University, Laboratory for Computational Sensing and Robotics, Baltimore, Maryland, United States
X
Xiangyi Le
Johns Hopkins University, Laboratory for Computational Sensing and Robotics, Baltimore, Maryland, United States
S
Seonghoon Jang
Johns Hopkins University, Laboratory for Computational Sensing and Robotics, Baltimore, Maryland, United States; Johns Hopkins University, Department of Mechanical Engineering, Baltimore, Maryland, United States
S
Shuwen Wei
Johns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States
J
Justin Opfermann
Johns Hopkins University, Laboratory for Computational Sensing and Robotics, Baltimore, Maryland, United States; Johns Hopkins University, Department of Mechanical Engineering, Baltimore, Maryland, United States
M
Michael Kam
Johns Hopkins University, Laboratory for Computational Sensing and Robotics, Baltimore, Maryland, United States; Johns Hopkins University, Department of Mechanical Engineering, Baltimore, Maryland, United States
Axel Krieger
Axel Krieger
Associate Professor, Johns Hopkins University
Medical DevicesRobotics
Jin U. Kang
Jin U. Kang
Jacob Suter Jammer Professor of ECE, Johns Hopkins University
Biophotonics3-D OCT Intraoperative Imaging (Real-Time OCT)Optical Image/Sensor-Guided Medical Robotics and Surgical ToolsF